Grand Victoria Casino parking garage is a three-story structure with four corner stair towers and a central core tower. The on-grade parking level is asphalt pavement, and the above-grade floors and ramps are constructed of pre-topped precast concrete double tees supported by precast concrete beams and cast-in-place interior concrete columns. RRJ was retained by the owner to perform a condition assessment of the parking garage. The condition assessment identified areas of deterioration and distress in the floor sealant joints, expansion joint seals, double tees, and beams and columns.
Scope of Services
Location | Elgin, IL |
---|---|
Client | Grand Victoria Casino |
Team | Kurt Hoigard, George Mulholland, Cole Graveen |
Market | Parking |
Services | Building Assessments, Field & Laboratory Testing, Investigation + Repair Services |