Back

Lakeview East Cooperative Parking Garage

Investigation and repair

Constructed in 1973, this three-level parking garage serves an 18-story residential tower. When it exhibited water leakage through the decks and concrete distress, the owner engaged RRJ to determine the cause of concrete distress, evaluate the condition of concrete materials and check the strength and serviceability of the garage’s structural system. The investigation identified high chloride levels in the garage concrete, which would accelerate corrosion of the steel reinforcement.

Scope of Services

  • Review original architectural and structural drawings
  • Perform visual examination of concrete columns
  • Perform sounding survey of upper and middle concrete floor slab surfaces
  • Review prior condition survey
  • Prepare repair design documentation and methods
  • Develop concrete strengthening repairs
  • Design punching shear repairs at garage columns

Project Details

Location Chicago, IL
Client Lakeview East Cooperative
Team Kurt Hoigard, George Mulholland
Market Parking
Services Concrete Evaluation, Investigation + Repair Services, Repair & Restoration Design Services