East Monroe Drive Parking Garage

The garage is a two-story underground concrete structure utilizing a cast-in-place concrete flat slab design.  The design planned for a maximum of five feet of soil fill on the roof level.  A portion of the garage roof collapsed while the garage was under construction, and after workers were on site placing soil fill in the area of the collapse.  The contractor retained RRJ to investigate the cause of the collapse.  All available evidence indicated design deficiencies were the cause of the collapse and that the major cause was improper design use of bent truss reinforcing bars used to reinforce upturned slab panels.

Scope of Services

  • Investigate collapse
  • Perform in situ material sampling and testing
  • Conduct detailed design review
  • Conduct structural analysis
  • Conduct field site inspections
  • Perform concrete core tests, survey soil profile and density
  • Document concrete and construction joints

Project Details

Location Chicago, IL
Client S. A. Healy Company
Team Kurt Hoigard, Robert Kritzler, Brian Lammert
Market Parking
Services Investigation, Field & Laboratory Testing, Design & Peer Review, Failure Analysis